Skip to content
Book a call Sign in

November 27, 2026 · The Vespy Team

BOMA Measurement Standards: Rentable Area, Load Factor, and Remeasurement

What the BOMA standards measure, how rentable and usable area relate through the load factor, and what happens to shares when a building is remeasured.

Part of Managing Mixed-Use Properties: Commercial and Residential Under One Roof .

BOMA standards are the measurement methods most US commercial leases use to define how large a space is. They matter because rentable area drives both rent and the tenant’s share of recoveries, so a measurement change moves money.

The standards are published by the Building Owners and Managers Association International. The office standard most current leases reference is ANSI/BOMA Z65.1-2017.

One standard per property type

BOMA publishes separate standards because property types are measured differently:

  • Office, the most widely used, which allocates building and floor common areas to tenants
  • Retail, focused on gross leasable area in shopping centers and street retail
  • Industrial, with methods for single-tenant and multi-tenant buildings
  • Multi-unit residential, for apartment buildings
  • Mixed-use, for allocating shared areas between components such as retail and residential

A mixed-use building may need more than one: the retail space measured under the retail standard, the residential under its own, and the mixed-use standard to divide what they share.

Usable, rentable, and the load factor

Usable area is the space a tenant occupies. Rentable area adds the tenant’s share of common areas: the lobby, corridors, restrooms, mechanical rooms, and so on. The ratio between them is the load factor:

load factor = rentable area / usable area

A suite with 10,000 usable square feet in a building with a 1.15 load factor:

10,000 USF x 1.15 = 11,500 RSF

The tenant pays rent and recoveries on 11,500 square feet. Two buildings quoting the same rent per square foot can cost a tenant very different amounts if their load factors differ. The load factor calculator converts between them, and rentable vs. usable covers the definitions.

Methods within the office standard

The 2017 office standard offers two calculation methods. One carries forward the floor-by-floor approach of earlier editions, with different load factors on different floors. The other applies a single load factor across the whole building. Which one a building uses affects how common areas are spread, so the method should be stated alongside the measurement.

What happens when a building is remeasured

Owners sometimes remeasure under a newer edition, usually after a renovation, a sale, or a change in common areas. Rentable area often increases, because newer editions count some areas earlier editions did not.

Suppose a building remeasures from 100,000 to 104,000 RSF, and one tenant’s suite goes from 8,000 to 8,400 RSF:

Before    8,000 / 100,000 = 8.00% share
After     8,400 / 104,000 = 8.08% share

Rent per square foot times a larger area means more rent, and a larger share means more recoveries. Whether any of that applies depends on the lease:

  • Many leases stipulate the rentable area, stating it is not subject to remeasurement during the term.
  • Some allow remeasurement but only for future leases, or only at renewal.
  • Some allow the building denominator to change but fix the tenant’s area, which would lower the tenant’s share.

Apply the new measurement only where each lease permits it, and keep the old and new figures with the date of change. A tenant auditor will compare the denominator used in the reconciliation with the one in the lease. Calculating pro-rata share covers why the denominator is the number most worth pinning down.

Practical checks

  • Record the standard and edition named in each lease
  • Keep the measurement report, with the date and the firm that produced it
  • Confirm that the sum of tenant shares plus vacant space equals 100% of the building
  • In mixed-use buildings, confirm the commercial and residential areas add up to the total

The mixed-use property management guide covers how measurement feeds cost allocation, and mixed-use property management software keeps rentable area on each suite and lease.

Common questions

What are BOMA standards?

BOMA standards are methods for measuring building floor area published by the Building Owners and Managers Association International, many adopted as ANSI standards. Separate standards cover office, retail, industrial, multi-unit residential, and mixed-use properties.

What is the current BOMA office standard?

The office standard most current commercial leases reference is ANSI/BOMA Z65.1-2017. Older leases often cite the 1996 or 2010 editions, and the edition named in the lease is the one that governs that lease.

What is the difference between rentable and usable square feet?

Usable square feet is the space a tenant actually occupies. Rentable square feet adds the tenant's share of common areas such as lobbies, corridors, and restrooms, so rentable area is always the larger figure.

See what your firm could automate.

We look at your PMS and your week, then tell you where to start.

Free intro call · No commitment